HS600 Ultrasonic Flaw Detector

Measuring Range and Measuring Error

Range of scanning: 0 mm ~10000 mm

Resolution for scanning: 0.1mm (2.5mm ~100mm)

1mm (100 mm ~5000mm)

Range of gain: 0dB ~120 dB

D-Delay: -20μs+3400μs

P-Delay: 0μs99.99μs

Sound speed : 1000 m/s15000m/s

Operation Environment

Temperature: -10~50

Humidity: 20%90%RH

Free of strong magnetic field and corrosion.

Power supply

Li battery 7.4V 4800mAh

Overall Dimension and Weight

Overall dimension: 240mm×150mm×50mm

Weight: 1.6kg

Performance Features

l Automated calibration of transducer Zero Offset and/or Velocity

l Automated gainPeak Hold and Peak Memory

l Automated display precise flaw location(Depth dlevel pdistance samplitudesz dBф)

l Automated switch three staff gauge ((Depth dlevel pdistance s)

l 100 independence setup, any criterion can be input freely, we can work in the scene without test block

l Big memory of 300 A graph.

l Gate and DAC alarmAcoustic-Optical alarm;

l RS232/USB portcommunication with pc is easy

l The embeded software can be online updated

l Li battery, continue working time up to 10 hours;

l Display freeze;

l Automated echo degree;

l Angles and K-value;

l Lock and unlock function of system parameters;

l Dormancy and screen savers;

l Electronic clock calendar ;

l Two gates setting and alarm indication;

l High-speed capture and very low noise;

l DACAVGB Scan ; Solid metal housing ;

l Automated calculate the size of the flaw with w ide bottom type in AVG function.

l AWS D1.1

l 6dB DAC functions;

l Automated make video of test process and play;

l Provides high contrast viewing of the waveform from bright, direct sunlight to completae darkness and easy to

read from all angles;

l Powerful pc software and reports can be export to excel;

Technical Parameters

Designation

Technical Data

Range of scanning (mm)

Range of scanning (mm)010000

Steps: 2.5,5,10,20, 30,40,50,60,70,80,90, 100,150,200, 250, 300, 350,400,450,500,600,700,800,900,1000,2000,3000,4000,5000,6000,7000,8000,10000

Adjusting step: 0.1mm2.5 mm99.9mm),1mm100mm10000mm

D-delay (ms)

D-delay (ms)-20+3400

Steps: -20,-10,0.0, 10, 20, 50,100,150,200,250,300,350,400,450,500, 600,

700,800,900,1000,1500,2000,2500,3000,3400.

Adjusting steps: 0.1-20ms999.9ms),11000ms3400ms

P-delay (ms)

P-delay0.099.99

Adjusting steps: 0.01

MTLVELm/s

MTLVEL1000~15000

7 fixed levels: 2260,2730,3080,3230,4700,5920,6300,12000

Adjusting steps: 1

Working mode

Single probe (receiving and sending), double probe (one for receiving and another for sending), transmission (transmission probe)

Frequency Range (MHz)

0.5~15

Gain adjustment (dB)

0120

Adjusting step: 0.00.10.512612

Reject

0%80% of screen height, step: 1%

Vertical linear error

Vertical linear error is not more than 3%

Horizontal linear error

Not more than 0.2% in the scanning range

Sensitivity Leavings

≥62 dB

Dynamic range

≥34dB

Alarm

Three modes, i.e. forbidden wave, loss wave and auto

A-Scan display area

Full screen or local

A-Scan display freezing and de-freezing A-Scan filling

Data save

300 A-Scan images (including setting of instrument)

Standard communication interface with PC

RS232/USB

Measuring unit

mm/inch

Battery

Li battery 7.4V 4800mAh

Power adaptor

Input 100V240V/50Hz60Hz

Output 9VDC/1.5A

Working temperature

-10℃~50℃

Working humidity

20%~90%

Port type

BNC / LEMO

Overall dimension (mm)

240×150×50

Weight (kg)

1.6

Standard Configurations and Options

Standard Configuration

Table 1.1 List of standard configurations

Designation

Quantity

Main unit

1

1.5A/9V power adaptor

1

probe connecting cable

2

Carrying case

1

Instruction manual

1

Straight probe

10mm 4MHz (One)

Angle probe

8×9 60°4MHz (One)

Options

Table 1.2 List of options

Designation

Quantity

Serial cable

1 (9 pin)

Communication software for PC

1 set


Send an inquiry for this product
Subject:
Name:
Telphone:
E-mail:
Content: