HS500 Ultrasonic Flaw Detector

Performance Features

l Automated calibration of transducer Zero Offset and/or Velocity ;

l Automated gain、Peak Hold and Peak Memory ;

l Automated display precise flaw location(Depth d、level p、distance s、amplitude、sz dB、ф) ;

l Automated switch three staff gauge ((Depth d、level p、distance s) ;

l 100 independence setup, any criterion can be input freely, we can work in the scene without test block ;

l Big memory of 300 A graph.

l Gate and DAC alarm ;Acoustic-Optical alarm;

l RS232/USB port, communication with pc is easy ;

l The embeded software can be online updated ;

l Li battery, continue working time up to 10 hours ;

l Display freeze;

l Automated echo degree;

l Angles and K-value;

l Lock and unlock function of system parameters;

l Electronic clock calendar ;

l Two gates setting and alarm indication;

l High-speed capture and very low noise;

l DAC、AVG ; Solid metal housing;

l Automated calculate the size of the flaw with w ide bottom type in AVG function.

l AWS D1.1 ;

l 6dB DAC functions;

l Provides high contrast viewing of the waveform from bright, direct sunlight to completae darkness and easy to read from all angles;

l Powerful pc software and reports can be export to excel;

Measuring Range and Measuring Error

Range of scanning: 0 mm ~6000 mm

Resolution for scanning: 0.1mm (2.5mm ~100mm) 1mm (100 mm ~5999mm)

Range of gain: 0dB ~100 dB

D-Delay: -20µs~ +3400µs

P-Delay: 0µs~ 99.99µs

Sound speed : 1000 m/s~ 15000m/s

Operation Environment

Temperature: -10~50

Humidity: 20%~ 90%RH

Free of strong magnetic field and corrosion.

Power supply

Li battery 7.4V 4800mAh

Overall Dimension and Weight

Overall dimension: 240mm×150mm×50mm

Weight: 1.6kg

Technical Parameters

Designation

Technical Data

Range of scanning (mm)

Range of scanning (mm): 0~ 6000

Steps: 2.5,5,10,20, 30,40,50,60,70,80,90, 100,150,200, 250, 300, 350, 400, 450,500,600,700,800,900,1000,2000,3000,4000,5000,6000

Adjusting step: 0.1mm(2.5 mm~ 99.9mm), 1mm(100mm~ 6000mm)

D-delay (ms)

D-delay (ms): -20~ +3400

Steps: -20,-10,0.0, 10, 20, 50,100,150,200,250,300,350,400,450,500, 600,

700,800,900,1000,1500,2000,2500,3000,3400.

Adjusting steps: 0.1(-20ms~ 999.9ms), 1(1000ms~ 3400ms)

P-delay (ms)

P-delay: 0.0~ 99.99         Adjusting steps: 0.01

MTLVEL(m/s)

MTLVEL: 1000~ 15000

7 fixed levels: 2260,2730,3080,3230,4700,5920,6300, 12000

Adjusting steps: 1

Working mode

Single probe (receiving and sending), double probe (one for receiving and another for sending), transmission (transmission probe)

Frequency Range (MHz)

0.5~15

Gain adjustment (dB)

0~ 100

Adjusting step: 0.0, 0.1, 0.5, 1, 2, 6, 12

Reject

0%~ 80% of screen height, step: 1%

Vertical linear error

Vertical linear error is not more than 3%

Horizontal linear error

Not more than 0.2% in the scanning range

Sensitivity Leavings

≥62 dB

Dynamic range

≥34dB

Alarm

Three modes, i.e. forbidden wave, loss wave and auto

A-Scan display area

Full screen or local

A-Scan display freezing and de-freezing A-Scan filling

Data save

300 A-Scan images (including setting of instrument)

Standard communication interface with PC

RS232/USB

Measuring unit

mm/inch

Battery

Li battery 7.4V 4800mAh

Power adaptor

Input 100V~ 240V/50Hz~ 60Hz

Output 9VDC/1.5A

Working temperature

-10℃~ 50℃

Working humidity

20%~ 90%

Port type

BNC / LEMO

Overall dimension (mm)

240×150×50

Weight (kg)

1.6

Standard Configuration

Table 1.1 List of standard configurations

Designation

Quantity

Main unit

1

1.5A/9V power adapter

1

probe connecting cable

2

Carrying case

1

Instruction manual

1

Straight probe

10mm 4MHz (One)

Angle probe

8×9 60°4MHz (One)

Options

Table 1.2 List of options

Designation

Quantity

Serial cable

1 (9 pin)

Communication software for PC

1 set


Send an inquiry for this product