Products
- Electronic Universal Testing Machine
- Hydraulic Universal Testing Machine
- Impact Testing Machine
- Compression Testing Machine
- Torsion Testing Machine
- Bending Testing Machine
- Spring Testing Machine
- Hardness Tester
- Other Testing Equipment
- Horizontal TensileTesting Machine
- Friction and Wear Testing Machine
- Metallographic Series
- Thickness Gauge
- Flaw Detector Equipment
- Force Gauge & Tension Meters
- Surface Roughness Tester
- Ultrasonic Flowmeter
- Cupping Testing Machine
- Cupping Testing Machine
- Creeping Testing Machine
- Fatigue Testing Machine
- Quick Forging Testing Machine
- Other Testing
- Other Testing Equipment
Contact Us
Jinan Hensgrand Instrument Co., Ltd.
Add: 4915,West jingshi Road,jinan 250012,PR CHINA.
Tel: 0086-15910081986
Fax: 0086-531-81901323
Website:www.hssdgroup.com
NDT Digital Display Drop Hammer Impact Test Equipment

1. Application:
The drop hammer impact Test machine is mainly used for non-ferritic steels ductility transition temperature of the sample drop weight method, the Test method is a certain quality of the hammer raised to a certain height, then there is static released, hammer body free fall impact to the sample surface, thereby determining the impact resistance of the sample. The drop hammer impact test machine integrating mechanical, electrical, automatic control technology, and to achieve a lifting hammer, feeding, shock, grab the hammer fully automated process. In addition to the testing machine is equipped with multi-channel protection measures, greatly improving the safety of operating personnel and equipment use. This machine is applicable for nil ductility transition temperature Testing of ferrite steel.
2. Standards:
ASTM E208-2006,GB/T 6803-1986, API5L3,ASTM E436-80,
ASTM E604-83
3. Main Technical Specifications:
Model |
NDT -800 |
NDT -3000 |
NDT -4000 |
NDT-6000 |
Max impact energy(J) |
800 |
3000 |
4000 |
6000 |
Min impact energy(J) |
300 |
350 |
600 |
750 |
Hammer quality (Kg) |
70 |
70 |
80 |
80 |
Main hammer body quality error |
±1% |
|||
Impact height (mm) |
750mm~3200 |
|||
Impact speed (m/s) |
3.8-7.6 |
|||
Lifting hammer speed (m/min) |
7 |
|||
Height test resolution(mm) |
0.1 |
|||
Height test error(mm) |
≤±10 |
|||
Hammer blade hardness |
HRC≥50 |
|||
Hammer blade radius of curvature |
R25mm |
|||
Bearing hardness |
HRC58~62 |
|||
Hammer blade center、Sample center and Support center deviation (mm) |
≤±2.5 |
|||
Sample bearing span(mm) |
P-1:305 P-2、P-3:100 |
|||
Sample size(mm)(length×width×thickness) |
P-1 sample:(360±1)×(90±2)×(25±2.5) P-2 sample:(130±1)×(50±1)×(20±1) P-3 Sample:(130±1)×(50±1)×(16±0.5) |
|||
High Low temperature device |
-70℃ -- 150℃ |